Compare
Do different monitors agree?
Delhi’s official stations (CPCB, DPCC, IMD, IITM) set beside other monitors (the US Embassy’s reference monitor and residents’ low-cost sensors) and beside the model estimates many apps show. Compared on PM2.5 in µg/m³, hour by hour, using only the hours both have, over the last 30 days.
Compare any station, any source ↓ · Model estimates (Google, CAMS) ↓ · Official stations against each other ↓
Compare any station, any source
Choose a station and a source on each line: what the station measured, or Google's or the CAMS model's estimate. Hourly PM2.5, last 30 days. The address updates, so you can share it.
Loading stations…
Right now The newest PM2.5 reading from each independent monitor, beside the newest from its nearest official station. Single readings can differ for many reasons; the hour-by-hour comparisons below say more.
- US Embassy, Chanakyapuri Reference monitor236vs151µg/m³ PM2.5 · nearest official: Talkatora Garden (DPCC)
- Air Check Low-cost sensor307vs–µg/m³ PM2.5 · nearest official: ITO (CPCB)
- Anand Lok Low-cost sensor372vs263µg/m³ PM2.5 · nearest official: Sirifort (CPCB)
- GK1 (Oberoi Terrace) Low-cost sensor374vs185µg/m³ PM2.5 · nearest official: Nehru Nagar (DPCC)
- Santushti Apartments Low-cost sensor254vs242µg/m³ PM2.5 · nearest official: JNU (DPCC)
US Embassy, Chanakyapuri Reference monitor
A beta-attenuation reference instrument run by the US Embassy, published through the US EPA’s AirNow. Independent of India’s official network.
OpenAQ lists this monitor at a point near the American Center on KG Marg, which the World Air Quality Index project noted in 2016 was the wrong location; it is at the US Embassy in Chanakyapuri, so stations are paired by the Embassy’s position.
US Embassy, Chanakyapuri vs Talkatora Garden DPCC · 2.7 km
Over 319 hours with readings from both, the US Embassy monitor read typically 15 µg/m³ (10%) higher than Talkatora Garden (DPCC, 2.7 km away). The two rose and fell closely together.
US Embassy, Chanakyapuri vs Lodhi Road IITM · 3.4 km
Over 283 hours with readings from both, the US Embassy monitor read typically 69 µg/m³ (109%) higher than Lodhi Road (IITM, 3.4 km away). The two broadly rose and fell together.
US Embassy, Chanakyapuri vs Lodhi Road IMD · 3.8 km
Over 310 hours with readings from both, the US Embassy monitor read typically 73 µg/m³ (99%) higher than Lodhi Road (IMD, 3.8 km away). The two rose and fell closely together.
Air Check Low-cost sensor
A low-cost optical sensor (AirGradient) run by a resident or organisation. Low-cost sensors can over-read in humid air and drift over time; we show its readings as published, without our own correction.
Air Check vs ITO CPCB · 0.9 km
Over 329 hours with readings from both, the Air Check sensor read typically 8 µg/m³ (6%) higher than ITO (CPCB, 0.9 km away). The two rose and fell closely together.
Air Check vs Major Dhyan Chand National Stadium DPCC · 1.4 km
Over 341 hours with readings from both, the Air Check sensor read typically 86 µg/m³ (105%) higher than Major Dhyan Chand National Stadium (DPCC, 1.4 km away). The two rose and fell closely together.
Air Check vs Lodhi Road IMD · 3.5 km
Over 341 hours with readings from both, the Air Check sensor read typically 102 µg/m³ (129%) higher than Lodhi Road (IMD, 3.5 km away). The two broadly rose and fell together.
Anand Lok Low-cost sensor
A low-cost optical sensor (AirGradient) run by a resident or organisation. Low-cost sensors can over-read in humid air and drift over time; we show its readings as published, without our own correction.
Anand Lok vs Sirifort CPCB · 1.0 km
Over 355 hours with readings from both, the Anand Lok sensor read typically 46 µg/m³ (29%) higher than Sirifort (CPCB, 1.0 km away). The two broadly rose and fell together.
Anand Lok vs Jawaharlal Nehru Stadium DPCC · 2.8 km
Over 353 hours with readings from both, the Anand Lok sensor read typically 104 µg/m³ (105%) higher than Jawaharlal Nehru Stadium (DPCC, 2.8 km away). The two rose and fell closely together.
Anand Lok vs R K Puram DPCC · 3.2 km
Over 345 hours with readings from both, the Anand Lok sensor read typically 92 µg/m³ (97%) higher than R K Puram (DPCC, 3.2 km away). The two rose and fell closely together.
GK1 (Oberoi Terrace) Low-cost sensor
A low-cost optical sensor (AirGradient) run by a resident or organisation. Low-cost sensors can over-read in humid air and drift over time; we show its readings as published, without our own correction.
GK1 (Oberoi Terrace) vs Nehru Nagar DPCC · 2.1 km
Over 352 hours with readings from both, the GK1 (Oberoi Terrace) sensor read typically 86 µg/m³ (77%) higher than Nehru Nagar (DPCC, 2.1 km away). The two rose and fell closely together.
GK1 (Oberoi Terrace) vs Sirifort CPCB · 2.7 km
Over 355 hours with readings from both, the GK1 (Oberoi Terrace) sensor read typically 55 µg/m³ (34%) higher than Sirifort (CPCB, 2.7 km away). The two broadly rose and fell together.
GK1 (Oberoi Terrace) vs CRRI Mathura Road IMD · 3.0 km
Over 335 hours with readings from both, the GK1 (Oberoi Terrace) sensor read typically 60 µg/m³ (37%) higher than CRRI Mathura Road (IMD, 3.0 km away). The two rose and fell closely together.
Santushti Apartments Low-cost sensor
A low-cost optical sensor (AirGradient) run by a resident or organisation. Low-cost sensors can over-read in humid air and drift over time; we show its readings as published, without our own correction.
Santushti Apartments vs JNU DPCC · 2.4 km
Over 354 hours with readings from both, the Santushti Apartments sensor read typically 15 µg/m³ (11%) higher than JNU (DPCC, 2.4 km away). The two rose and fell closely together.
Santushti Apartments vs Sri Aurobindo Marg DPCC · 4.0 km
Over 355 hours with readings from both, the Santushti Apartments sensor read typically 58 µg/m³ (65%) higher than Sri Aurobindo Marg (DPCC, 4.0 km away). The two rose and fell closely together.
Santushti Apartments vs IIT Delhi IITM · 4.5 km
Over 338 hours with readings from both, the Santushti Apartments sensor read typically 28 µg/m³ (19%) higher than IIT Delhi (IITM, 4.5 km away). The two rose and fell closely together.
Model estimates against the stations Models estimate air quality from emissions, weather and (for Google) other data; apps and maps often show these instead of a nearby station. Here each model’s hourly PM2.5 at each station’s position is set against what that station measured, hour by hour.
Google’s air-quality model at each station’s exact position (the estimate behind Google Maps’ air-quality layer). It also draws on station data, so it isn’t fully independent of them.
Over 15,340 station-hours, Google’s estimates were about the same as what the stations measured, within 25% in 64% of hours (correlation 0.81).
At 39 of 46 stations its typical estimate is within 5 µg/m³ of what the station itself measured: near a station, Google largely reflects that station.
CAMS
The European Copernicus model (CAMS), via Open-Meteo. Its grid squares are about 25 km across, so it gives a regional background, not street-level detail.
Over 15,183 station-hours, CAMS’s estimates were typically 13 µg/m³ (12%) lower than what the stations measured, within 25% in 31% of hours (correlation 0.30).
| Station | Measured (median) | Google − measured | CAMS − measured |
|---|---|---|---|
| PusaIMD | 172 | −91 | −51 |
| RohiniDPCC | 133 | 0 | −26 |
| WazirpurDPCC | 139 | 0 | −25 |
| MundkaDPCC | 139 | 0 | −24 |
| Lodhi RoadIITM | 72 | +16 | +40 |
| Aya NagarIMD | 134 | +11 | −29 |
| Burari CrossingIMD | 166 | −9 | −54 |
| Jawaharlal Nehru StadiumDPCC | 102 | 0 | +8 |
| Commonwealth Sports ComplexDPCC | 161 | −8 | −54 |
| ShadipurCPCB | 121 | +8 | −18 |
| PusaDPCC | 85 | −5 | +15 |
| IIT DelhiIITM | 129 | −5 | −14 |
| BawanaDPCC | 147 | +4 | −34 |
| JNUDPCC | 134 | −4 | −22 |
| IHBASCPCB | 106 | +3 | −13 |
| SirifortCPCB | 167 | −3 | −47 |
| R K PuramDPCC | 116 | 0 | +3 |
| Talkatora GardenDPCC | 138 | −3 | −40 |
| NSUT JaffarpurDPCC | 170 | −3 | −73 |
| ITOCPCB | 166 | −2 | −50 |
| Sonia ViharDPCC | 119 | −2 | −9 |
| Nehru NagarDPCC | 124 | +2 | −12 |
| JahangirpuriDPCC | 140 | −2 | −35 |
| Okhla Phase-2DPCC | 101 | +2 | +12 |
| PatparganjDPCC | 101 | −2 | 0 |
| Punjabi BaghDPCC | 156 | +2 | −53 |
| Major Dhyan Chand National StadiumDPCC | 86 | −2 | +20 |
| CRRI Mathura RoadIMD | 161 | −2 | −34 |
| AlipurDPCC | 119 | −1 | −9 |
| NarelaDPCC | 125 | −1 | −7 |
| Vivek ViharDPCC | 143 | +1 | −22 |
| Lodhi RoadIMD | 75 | −1 | +31 |
| IGNOU_Maidan GarhiDPCC | 82 | +1 | +24 |
| IGI Airport (T3)IMD | 84 | −1 | +23 |
| Sri Aurobindo MargDPCC | 90 | −1 | +18 |
| Dr. Karni Singh Shooting RangeDPCC | 97 | −1 | +8 |
| Chandni ChowkIITM | 152 | +1 | −50 |
| Mandir MargDPCC | 99 | 0 | +2 |
| North CampusIMD | 168 | 0 | −61 |
| NSIT DwarkaCPCB | 67 | 0 | +27 |
| NajafgarhDPCC | 92 | 0 | −2 |
| Ashok ViharDPCC | 116 | 0 | −12 |
| Anand ViharDPCC | 132 | 0 | −20 |
| Dwarka-Sector 8DPCC | 106 | 0 | +10 |
| Cantonment AreaDPCC | 61 | 0 | +43 |
| DTUCPCB | 184 | 0 | −70 |
Typical (median) hour-by-hour difference in µg/m³ over the last 30 days. “+” means the model estimated more than the station measured. Sorted by the size of the Google difference.
Model data: Google Air Quality API (history); Copernicus Atmosphere Monitoring Service (CAMS) global forecasts via Open-Meteo (CC BY 4.0). Estimates are not measurements.
Official stations against each other Each official station compared, hour by hour, with the middle reading of the other official stations within 5 km. Listed only if it read at least 1.5 times higher, or at most two-thirds, over 3+ days of matched hours. Stations listed at the same location are compared directly.
Official stations close together should usually read in the same range. These don’t. That isn’t evidence of a fault: a station in a park or campus can genuinely see cleaner air than one by a main road. But a large, steady gap is worth knowing about, and some of these places are only a few hundred metres apart.
Pusa IMD vs Pusa DPCC same location
These two official monitors are listed at the same location. Over 1212 hours with readings from both, Pusa (IMD) typically read 169 µg/m³ and Pusa (DPCC) 84 µg/m³: about 2.0 times as much, with a correlation of 0.81.
Stations that read well above or below their neighbours
Over 1305 hours, it typically read 166 µg/m³ while the middle of 8 official stations within 5 km read 103: consistently higher. Google estimates 2 µg/m³ less than this station; CAMS estimates 50 µg/m³ less than this station.
Over 1296 hours, it typically read 84 µg/m³ while the middle of 3 official stations within 5 km read 144: consistently lower. Google estimates 5 µg/m³ less than this station; CAMS estimates 15 µg/m³ more than this station.
Over 1378 hours, it typically read 167 µg/m³ while the middle of 8 official stations within 5 km read 105: consistently higher. Google estimates 3 µg/m³ less than this station; CAMS estimates 47 µg/m³ less than this station.
Over 1233 hours, it typically read 72 µg/m³ while the middle of 8 official stations within 5 km read 113: consistently lower. Google estimates 16 µg/m³ more than this station; CAMS estimates 40 µg/m³ more than this station.
Over 1382 hours, it typically read 137 µg/m³ while the middle of 5 official stations within 5 km read 91: consistently higher. Google estimates 3 µg/m³ less than this station; CAMS estimates 40 µg/m³ less than this station.
Over 1342 hours, it typically read 75 µg/m³ while the middle of 7 official stations within 5 km read 116: consistently lower. Google estimates 1 µg/m³ less than this station; CAMS estimates 31 µg/m³ more than this station.
What could explain a gap: genuinely different surroundings (traffic, greenery, construction), where the inlet is placed, instrument type or calibration, or a data problem. What would settle it: the agencies’ calibration and maintenance records, or a temporary reference monitor placed beside both.
What this can and can’t tell you
- Monitors a few kilometres apart can genuinely measure different air: traffic, construction, burning and wind change PM2.5 over short distances.
- Instruments differ. Official stations and the Embassy use reference-grade methods; low-cost sensors estimate PM2.5 from scattered light and tend to over-read in humid air.
- A difference is not proof that either monitor is wrong. Consistent differences in the same direction are the signal worth noticing.
- “Typical difference” is the median of hour-by-hour differences (independent minus official). “Within 25%” counts hours where the two were within 25% of the official value, or 10 µg/m³ when air was cleaner.
- Values are as published by OpenAQ, which relays all of these monitors. Our unit checks apply; nothing is smoothed or corrected.
- Model estimates are not measurements. A model that differs from a station isn’t necessarily wrong about the wider area, and a station isn’t necessarily wrong about its own spot.