Methodology · version 2.5 (29 Nov 2026)
How this works, and what it can't tell you
Every hour we ask the public OpenAQ feed for the latest reading from each official station in Delhi. Everything on this site is worked out from those hourly checks. This page explains each rule, so anyone can check or reproduce our numbers.
Fresh data and missing readings
Fresh data: a station's latest PM2.5 reading is less than 3 hours old at the time of our check. OpenAQ's Delhi data normally arrives 2 to 3 hours after it was measured, so a shorter limit would flag normal delays.
No fresh data (technically “stale”): the latest reading is 3 hours old or more. No PM2.5 data on record: the source has never supplied PM2.5 for that station.
Expected readings (station-hours): one PM2.5 reading per official station per hourly check. Availability is the share of those that were fresh. Our own failed checks are left out of both sides; they say nothing about the stations.
Interruption: a run of consecutive hourly checks in which a station had no fresh data, not counting checks that fell in a source interruption. Lengths are given in hourly checks. Because “no fresh data” starts 3 hours after the last reading, the real time without new data is roughly the number of checks plus 3 hours.
Source interruptions and our own failures
When 60% or more of official stations have no fresh data in the same check, we call it a possible source interruption. Dozens of independent stations, run by different agencies, rarely fail at the same moment, so the likeliest cause is upstream: the agencies' systems or OpenAQ. That is a reasoned guess, not a confirmed fact. We haven't been able to check these events against the agencies' own portals, so the cause is officially unknown.
During a source interruption we don't count the silence against individual stations, and comparisons that would be misleading are paused.
Our own failures are separate: when our request for a station fails, that station is marked “our check failed” and isn't counted as silent. If the whole site stops updating, every page shows a warning once it's more than 3 hours old.
Six separate questions instead of one score
- Freshness
- How recently did the station send a reading?
- Availability
- What share of expected readings arrived?
- Continuity
- How often do interruptions happen, and how long do they last? Two stations with 80% availability can differ a lot: one long outage versus many short ones.
- Consistency
- Is a reading impossible (negative), implausible (exactly zero for particles), frozen (the same value for 6+ hours) or statistically unusual?
- Source integrity
- Was the upstream feed working when the reading was due?
- Measurement validity
- Is the reading correct? We can't verify this. We have no independent reference instruments, so fresh data may still be wrong.
Units
Gas readings are shown in µg/m³ (CO in mg/m³, NOx in ppb, matching CPCB). Converting between ppb and µg/m³ uses 25 °C and 1 atm (molar volume 24.45 L): µg/m³ = ppb × molecular weight ÷ 24.45. The published value and label are always shown next to the converted one.
Some unit labels on the public feed are wrong. We checked them against the data itself. For example, CPCB's NOx is NO + NO₂, and at 44 of 45 stations that only adds up if NO and NO₂ are in µg/m³ and NOx in ppm. SO₂ can't be checked that way; it's read as µg/m³ because it comes from the same feed with the same label and CPCB reports it in µg/m³. That one is an inference, not a proof.
| Pollutant | Label as published | Read as | Why |
|---|---|---|---|
| NO | ppb | µg/m³ | Checked against the data (see above); shown in µg/m³ |
| NO₂ | ppb | µg/m³ | Checked against the data (see above); shown in µg/m³ |
| NOx | ppb | ppm | Checked against the data (see above); shown in ppb |
| SO₂ | ppb | µg/m³ | Checked against the data (see above); shown in µg/m³ |
| CO | ppb, value under 50 | mg/m³ | Real CO is never below ~100 ppb, so small values must be mg/m³ (CPCB's unit) |
| Gas | Molecular weight |
|---|---|
| NO₂ | 46.0055 |
| SO₂ | 64.066 |
| O₃ | 47.998 |
| CO | 28.01 |
| NO | 30.006 |
Indicative AQI
CPCB's method: each pollutant's average over its window gives a sub-index by linear interpolation within a band; the AQI is the highest sub-index. It needs at least three pollutants, one of them PM2.5 or PM10. Windows end at each pollutant's newest reading. Readings that are frozen, negative or zero are left out, and so is any pollutant with no fresh data. Above “Very poor” we show “401+”, because the top of the Severe band isn't a fixed concentration. It's not CPCB's official AQI and can differ from it. Each station card shows the exact inputs.
| Pollutant | Good ≤ | Satisfactory ≤ | Moderate ≤ | Poor ≤ | Very poor ≤ | Window |
|---|---|---|---|---|---|---|
| PM10 | 50 | 100 | 250 | 350 | 430 | 24 h (≥16 h of data) |
| PM2.5 | 30 | 60 | 90 | 120 | 250 | 24 h (≥16 h of data) |
| NO₂ | 40 | 80 | 180 | 280 | 400 | 24 h (≥16 h of data) |
| O₃ | 50 | 100 | 168 | 208 | 748 | 8 h (≥6 h of data) |
| CO | 1 | 2 | 10 | 17 | 34 | 8 h (≥6 h of data) |
| SO₂ | 40 | 80 | 380 | 800 | 1600 | 24 h (≥16 h of data) |
A second source: official AQI from the Delhi government
When a station has no fresh reading on OpenAQ, we show its AQI from aqi.delhi.gov.in, the portal of the Department of Environment, Government of NCT of Delhi (data: CPCB and DPCC; reused under the Government Open Data License – India). It is shown only if its hour is under 3 hours old when the page is built. It is India's AQI, which uses averages over many hours, so it isn't comparable with the hourly PM2.5 elsewhere on this site. The portal's figures are provisional. We don't count them as readings, add them to our records or downloads, or use them in any of our figures. Stations we can't match with certainty, including both Pusa monitors, don't get one.
Readings worth a second look
We separate readings that can't be right from readings that are merely unusual:
- Impossible: a negative concentration.
- Implausible: particulate matter of exactly zero.
- Not changing: the same value for at least 6 hours in a row, which suggests a frozen instrument or feed.
- Possibly unusual: more than 4× the median of Delhi's official stations for that pollutant and above CPCB's “Satisfactory” band, so Moderate or worse (for NO and NOx, above 80). The second condition matters at night, when ozone and NO are low everywhere and an ordinary reading can be many times the median. A real local event (a fire, construction, traffic) can also do this, so it's flagged, not rejected.
Every warning on a station card says which rule it matched and shows the numbers.
Four different times
Measured: the hour the station's reading refers to, as published. Retrieved: when our hourly check fetched it. Page built: when this page was generated. Uploaded: pages go live every 2 hours. The time a reading first appeared on OpenAQ isn't published, so we can't separate delays at the agency from delays at OpenAQ.
Daily records, events and downloads
Daily records cover one IST day (00:00–24:00). The share of expected readings counts one PM2.5 reading per official station per completed hourly check, as on the live page. A record is provisional for three days after the day ends, because the 72-hour sweep can still add late readings; then it becomes final and is never rewritten, so a shared link keeps its numbers. A later method change applies only to records that weren't final yet.
Events are detected automatically and worded as a record of what the feed showed, not a verdict on why:
- Feed pause: 60%+ of official stations silent at the same checks for 2+ checks in a row. The pause the feed takes most nights (starting 01:00–04:59 IST, up to 3 checks) is noted on the daily record but isn't an event unless it runs longer.
- Station gap: one station without fresh PM2.5 for 12+ checks while the rest of the network reported. Checks inside a feed pause neither count towards it nor end it.
- On our side: 2+ hours in which our own checks didn't run or couldn't reach the feed. These hours are left out of every availability figure.
Downloads (a zip per final day, and per complete month) contain every value the source published for official stations, with its units as published and as converted, the hour it covers, when our checks first saw it and any later revision; and every station's status at every hourly check. The RSS feeds announce events when they start and end, and one daily record a day.
What this site can't tell you
- Whether a station was physically switched off. A missing reading only means nothing new reached the public feed.
- Whether a reading is accurate.
- Why a source interruption happened.
- What the air is like between stations. Pollution can change a lot over short distances, and a nearby station isn't a measurement of your street.
- Your health risk. For that, use official guidance.
Changes to the method
- 2.5 · 29 Nov 2026: when an official station has no fresh reading on OpenAQ, we may show its official AQI from the Delhi government’s portal (rules above). Where shown, it takes the place of the estimate.
- 2.4 · 29 Nov 2026: when an official station is quiet, its station page and Your area may show an estimate, drawn with a dashed outline and a range so it can't be mistaken for a measurement. It is Google's model value for the station's position, scaled by how the station read against Google at that time of day over the past week. In 30 days of checks the measured value was within 0.74 to 1.36 times that estimate 80% of the time. Estimates are never counted as readings in any figure.
- 2.3 · 25 Nov 2026: the US Embassy's monitor is no longer counted as an official station (so the official count drops by one). It is run by the US government and published through AirNow, not by CPCB, DPCC, IMD or IITM. It and residents' low-cost sensors are now shown apart as independent monitors, with diamonds on the map and their own pages, and never counted in official figures. Daily records that were already final keep the earlier count.
- 2.2 · 24 Nov 2026: daily records, events, downloads and RSS feeds (rules above); each station's AQI shows which pollutant sets it.
- 2.1 · 24 Nov 2026: “possibly unusual” now also needs the value to be Moderate or worse; retired station IDs and stations with no PM2.5 sensor are no longer counted as interruptions; “since the last update” recognises when the earlier check fell in a source interruption.
- 2.0 · 23 Nov 2026: six separate data-quality questions; source interruptions shown as their own status; plain-language labels; evidence for every warning; corrected unit labels for NO, NO₂, NOx and SO₂ (since 23 Nov).
- 1.0 · 15 Nov 2026: hourly tracking starts.