Delhi Air Watch

Methodology · version 2.5 (29 Nov 2026)

How this works, and what it can't tell you

Every hour we ask the public OpenAQ feed for the latest reading from each official station in Delhi. Everything on this site is worked out from those hourly checks. This page explains each rule, so anyone can check or reproduce our numbers.

Fresh data and missing readings

Fresh data: a station's latest PM2.5 reading is less than 3 hours old at the time of our check. OpenAQ's Delhi data normally arrives 2 to 3 hours after it was measured, so a shorter limit would flag normal delays.

No fresh data (technically “stale”): the latest reading is 3 hours old or more. No PM2.5 data on record: the source has never supplied PM2.5 for that station.

Expected readings (station-hours): one PM2.5 reading per official station per hourly check. Availability is the share of those that were fresh. Our own failed checks are left out of both sides; they say nothing about the stations.

Interruption: a run of consecutive hourly checks in which a station had no fresh data, not counting checks that fell in a source interruption. Lengths are given in hourly checks. Because “no fresh data” starts 3 hours after the last reading, the real time without new data is roughly the number of checks plus 3 hours.

Source interruptions and our own failures

When 60% or more of official stations have no fresh data in the same check, we call it a possible source interruption. Dozens of independent stations, run by different agencies, rarely fail at the same moment, so the likeliest cause is upstream: the agencies' systems or OpenAQ. That is a reasoned guess, not a confirmed fact. We haven't been able to check these events against the agencies' own portals, so the cause is officially unknown.

During a source interruption we don't count the silence against individual stations, and comparisons that would be misleading are paused.

Our own failures are separate: when our request for a station fails, that station is marked “our check failed” and isn't counted as silent. If the whole site stops updating, every page shows a warning once it's more than 3 hours old.

Six separate questions instead of one score

Freshness
How recently did the station send a reading?
Availability
What share of expected readings arrived?
Continuity
How often do interruptions happen, and how long do they last? Two stations with 80% availability can differ a lot: one long outage versus many short ones.
Consistency
Is a reading impossible (negative), implausible (exactly zero for particles), frozen (the same value for 6+ hours) or statistically unusual?
Source integrity
Was the upstream feed working when the reading was due?
Measurement validity
Is the reading correct? We can't verify this. We have no independent reference instruments, so fresh data may still be wrong.

Units

Gas readings are shown in µg/m³ (CO in mg/m³, NOx in ppb, matching CPCB). Converting between ppb and µg/m³ uses 25 °C and 1 atm (molar volume 24.45 L): µg/m³ = ppb × molecular weight ÷ 24.45. The published value and label are always shown next to the converted one.

Some unit labels on the public feed are wrong. We checked them against the data itself. For example, CPCB's NOx is NO + NO₂, and at 44 of 45 stations that only adds up if NO and NO₂ are in µg/m³ and NOx in ppm. SO₂ can't be checked that way; it's read as µg/m³ because it comes from the same feed with the same label and CPCB reports it in µg/m³. That one is an inference, not a proof.

PollutantLabel as publishedRead asWhy
NOppbµg/m³Checked against the data (see above); shown in µg/m³
NO₂ppbµg/m³Checked against the data (see above); shown in µg/m³
NOxppbppmChecked against the data (see above); shown in ppb
SO₂ppbµg/m³Checked against the data (see above); shown in µg/m³
COppb, value under 50mg/m³Real CO is never below ~100 ppb, so small values must be mg/m³ (CPCB's unit)
GasMolecular weight
NO₂46.0055
SO₂64.066
O₃47.998
CO28.01
NO30.006

Indicative AQI

CPCB's method: each pollutant's average over its window gives a sub-index by linear interpolation within a band; the AQI is the highest sub-index. It needs at least three pollutants, one of them PM2.5 or PM10. Windows end at each pollutant's newest reading. Readings that are frozen, negative or zero are left out, and so is any pollutant with no fresh data. Above “Very poor” we show “401+”, because the top of the Severe band isn't a fixed concentration. It's not CPCB's official AQI and can differ from it. Each station card shows the exact inputs.

PollutantGood ≤Satisfactory ≤Moderate ≤Poor ≤Very poor ≤Window
PM105010025035043024 h (≥16 h of data)
PM2.530609012025024 h (≥16 h of data)
NO₂408018028040024 h (≥16 h of data)
O₃501001682087488 h (≥6 h of data)
CO121017348 h (≥6 h of data)
SO₂4080380800160024 h (≥16 h of data)

A second source: official AQI from the Delhi government

When a station has no fresh reading on OpenAQ, we show its AQI from aqi.delhi.gov.in, the portal of the Department of Environment, Government of NCT of Delhi (data: CPCB and DPCC; reused under the Government Open Data License – India). It is shown only if its hour is under 3 hours old when the page is built. It is India's AQI, which uses averages over many hours, so it isn't comparable with the hourly PM2.5 elsewhere on this site. The portal's figures are provisional. We don't count them as readings, add them to our records or downloads, or use them in any of our figures. Stations we can't match with certainty, including both Pusa monitors, don't get one.

Readings worth a second look

We separate readings that can't be right from readings that are merely unusual:

Every warning on a station card says which rule it matched and shows the numbers.

Four different times

Measured: the hour the station's reading refers to, as published. Retrieved: when our hourly check fetched it. Page built: when this page was generated. Uploaded: pages go live every 2 hours. The time a reading first appeared on OpenAQ isn't published, so we can't separate delays at the agency from delays at OpenAQ.

Daily records, events and downloads

Daily records cover one IST day (00:00–24:00). The share of expected readings counts one PM2.5 reading per official station per completed hourly check, as on the live page. A record is provisional for three days after the day ends, because the 72-hour sweep can still add late readings; then it becomes final and is never rewritten, so a shared link keeps its numbers. A later method change applies only to records that weren't final yet.

Events are detected automatically and worded as a record of what the feed showed, not a verdict on why:

Downloads (a zip per final day, and per complete month) contain every value the source published for official stations, with its units as published and as converted, the hour it covers, when our checks first saw it and any later revision; and every station's status at every hourly check. The RSS feeds announce events when they start and end, and one daily record a day.

What this site can't tell you

Changes to the method